| Sign In | Join Free | My benadorassociates.com |
|
Brand Name : TONHE
Model Number : Tonghe DC Power Distribution Panel
Certification : CE、ISO9001
Place of Origin : HeBei China
MOQ : 1
Price : Factory price
Payment Terms : T/T
Supply Ability : 15000 pcs per year
Delivery Time : 7-14 days after payment
Packaging Details : Carton
Product Model : TONHE AC Incoming & AC Distribution Panel
Rated Voltage : AC 380V / 220V ±20%
Rated Frequency : 50Hz / 60Hz
Protection Rating : IP30 / IP40 / IP54 (Optional)
Installation : Floor-standing
Cable Entry/Exit : Top/Bottom/Side Entry & Exit
Comm. Interface : RS485 / (MODBUS RTU/TCP) TH
Dc panel : Dc panel
Tonhe Electronics AC Incoming Panels and AC Feeder Panels are core low-voltage distribution equipment in power distribution systems, specifically designed for power plants, substations, data centers, and industrial facilities. Serving as the critical hub for energy distribution, these two cabinet types jointly form a stable and reliable AC power network. The AC Incoming Panel is responsible for introducing dual or multiple AC power sources from the grid, performing metering, protection, and switching to ensure continuous power input. The AC Feeder Panel precisely distributes energy from the busbar to various load circuits (such as DC charging panels, lighting, HVAC, maintenance power, etc.), providing comprehensive branch protection and monitoring. Designed with modularity and equipped with intelligent monitoring systems, both units deliver "zero-interruption" AC power assurance for critical infrastructure.
The AC Incoming Panel (also known as the Receiving Cabinet) serves as the "gateway" of the distribution system. Its primary function is to receive electrical energy from the external grid (typically AC 380V/220V) and introduce it into the cabinet busbar via the main circuit breaker. It integrates an Automatic Transfer Switch (ATS) for dual power sources, lightning surge protection, voltage/current metering, and main circuit protection. In the event of a main power failure, the incoming panel can automatically or manually switch to the backup power source rapidly, ensuring continuous supply and acting as the first line of defense for the safe operation of the entire distribution system.
The AC Feeder Panel (also known as the Distribution Cabinet or Outgoing Cabinet) acts as the "distribution center" of the power system. It draws energy from the Incoming Panel or Bus Tie Panel and distributes it to specific electrical equipment via multiple branch circuit breakers. In substation scenarios, it primarily supplies AC power to DC charging panels, emergency lighting, heating/dehumidification devices, maintenance sockets, and HVAC systems. The feeder panel features refined branch monitoring and protection capabilities, ensuring that a fault in a single circuit does not affect others, thereby achieving effective fault isolation.
| Parameter Item | AC Incoming Panel | AC Feeder Panel |
|---|---|---|
| Rated Voltage | AC 380V / 220V ±20% | AC 380V / 220V ±20% |
| Rated Frequency | 50Hz / 60Hz | 50Hz / 60Hz |
| Main Breaker Capacity | 100A - 6300A (Customizable) | Branch: 10A - 630A / Main: Same as Incoming |
| Short-time Withstand Current | 30kA - 50kA (1s) | 30kA - 50kA (1s) |
| Protection Rating | IP30 / IP40 / IP54 (Optional) | IP30 / IP40 / IP54 (Optional) |
| Installation | Floor-standing | Floor-standing |
| Cable Entry/Exit | Top/Bottom/Side Entry & Exit | Top/Bottom Entry & Exit |
| Comm. Interface | RS-485 / Ethernet (MODBUS RTU/TCP) | RS-485 / Ethernet (MODBUS RTU/TCP) |
| Operating Temp. | -10°C - +45°C | -10°C - +45°C |
Tonhe Electronics AC Incoming & AC Distribution Panel are designed, manufactured, and tested in strict compliance with the latest International Electrotechnical Commission (IEC) standards. This ensures global compatibility, safety, and reliability, meeting rigorous entry requirements for markets in Europe, America, and countries along the "Belt and Road" initiative.
| Standard | Standard Name | Scope & Core Value |
|---|---|---|
| IEC 61439-1:2020 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules | General Rules: Defines design verification, routine tests, and performance requirements. Replaces old IEC 60439, emphasizing responsibility between OEM and Assembler to ensure overall system safety. |
| IEC 61439-2:2020 | Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies | Core Product Standard: Specific requirements for power switchgear assemblies (like Incoming/Feeder Panels). Covers rigorous verification of temperature rise limits, dielectric properties, short-circuit withstand strength, IP ratings, and EMC. |
| IEC 60529 | Degrees of protection provided by enclosures (IP Code) | Protection Safety: Specifies enclosure dust and water protection levels (e.g., IP40/IP54), ensuring safe operation in harsh environments like dust or humidity. |
| IEC 61000-6-2 / 6-4 | Electromagnetic Compatibility (EMC) | Anti-Interference: - IEC 61000-6-2: Immunity standard for industrial environments, ensuring no malfunction under strong EMI. - IEC 61000-6-4: Emission standard, limiting electromagnetic pollution to the external environment. |
| IEC 60947 Series | Low-voltage switchgear and controlgear | Component Standards: Regulates performance of core components like circuit breakers and contactors (e.g., IEC 60947-2 for Breakers), ensuring world-class quality. |
|
|
AC Incoming Panel and AC Distribution Panel with Dual Power Auto Transfer Intelligent Metering Images |